| MODEL | S-120-5 | S-120-12 | S-120-24 | S-120-48 | |
| OUTPUT | DC voltage | 5V | 12V | 24V | 48V | 
| Rated current | 24A | 10A | 5A | 2.5A | |
| Current range | 0 ~ 24A | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | |
| Rated power | 120W | 120W | 120W | 120W | |
| Ripple & noise | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
| Voltage ADJ. range | ±10% | ±10% | ±10% | ±10% | |
| Setup,rise,hold time | 1000ms, 30ms,20ms/230VAC | ||||
| INPUT | Voltage range | 85~132VAC / 176~264VAC selected by switch 230~370VDC | |||
| Frequency range | 47 ~ 63Hz | ||||
| Efficiency | 79% | 82% | 82% | 83% | |
| Ac current | 2.4A/115VAC 1.2A/230VAC | ||||
| Inrush current | Cold start 45A | ||||
| Leakage current | <2mA/240VAC | ||||
| PROTECTION | Overload | 115 ~ 150% rated output power | |||
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
| Over voltage | 5.8~6.8V | 14~16.5V | 28~32V | 55~64V | |
| Protection type :Shut off | |||||
| ENVIRONMENT | Working temp,humidity | -10℃ ~ +60℃,20% ~ 90% RH non-condensing | |||
| Storage temp,humidity | -20℃ ~ +80℃,10% ~ 95% RH non-condensing | ||||
| Withstand vibration | 10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes | ||||
| SAFETY & EMC | Safety standard | Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved | |||
| Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| EMC standard | EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved | ||||
| OTHERS | MTBF | 400K hrs | |||
| Dimension | 199*98*38mm (L*W*H) | ||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
| 3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||