Tel: +86 577 62602806Phone: 86-18106781616E-mail: wode@wodeps.com
Mobile: 86-18106781616
Tel: +86 577 62602806
Fax: +86 577 62602807
E-mail: wode@wodeps.com
Add: Taikai 6 follor,Xiangyang Industrial Zone,Liushi Town, Yueqing City,Zhejiang Province, China
MODEL |
BG-20-12 |
BG-20-24 |
BG-20-36 |
BG-20-48 |
|
OUTPUT |
DC voltage |
12V |
24V |
36V |
48V |
Rated current |
1.67A |
0.84A |
0.56A |
0.42A |
|
Current range |
0 ~ 1.67A |
0 ~ 0.84A |
0 ~ 0.56A |
0 ~ 0.42A |
|
Rated power |
20W |
20.2W |
20.2W |
20.2W |
|
Ripple & noise |
100mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
|
Setup,rise,hold time |
500ms, 20ms,20ms/230VAC |
||||
INPUT |
Voltage range |
85~264VAC 120~370VDC |
|||
Frequency range |
47 ~ 63Hz |
||||
Efficiency |
80% |
81% |
81% |
83% |
|
Ac current |
0.55A/115VAC 0.35A/230VAC |
||||
Inrush current |
Cold start 30A |
||||
Leakage current |
<0.5mA/240VAC |
||||
PROTECTION |
Overload |
115 ~ 150% rated output power |
|||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||
Over voltage |
5.8~6.8V |
28~32V |
28~32V |
55~64V |
|
Protection type :Shut off |
|||||
ENVIRONMENT |
Working temp,humidity |
-20℃ ~ +60℃,20% ~ 90% RH non-condensing |
|||
Storage temp,humidity |
-20℃ ~ +85℃,10% ~ 95% RH non-condensing |
||||
Withstand vibration |
10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes |
||||
SAFETY & EMC |
Safety standard |
Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved |
|||
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||||
EMC standard |
EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved |
||||
OTHERS |
MTBF |
500K hrs |
|||
Dimension |
182*29*30mm (L*W*H) |
||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |
||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
|||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |