Tel: +86 577 62602806Phone: 86-18106781616E-mail: wode@wodeps.com
Mobile: 86-18106781616
Tel: +86 577 62602806
Fax: +86 577 62602807
E-mail: wode@wodeps.com
Add: Taikai 6 follor,Xiangyang Industrial Zone,Liushi Town, Yueqing City,Zhejiang Province, China
Model Specification |
HRU-300-12 |
HRU-300-24 |
HRU-300-36 |
HRU-300-48 |
|
OUTPUT |
DC voltage |
12V |
24V |
36V |
48V |
Rated output current |
25A |
12.5A |
8.3A |
6.3A |
|
Output current range |
0~25A |
0~12.5A |
0~8.3A |
0~6.3A |
|
DC power |
300W |
300W |
300W |
300W |
|
Voltage tolerance |
±1% |
±1% |
±1% |
±1% |
|
Ripple and noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
INPUT |
AC voltage range |
AC170-260V 47-63Hz:240-370VDC |
|||
Current |
4A/115V 2A/230V |
||||
Efficiency |
85% |
86% |
86% |
86% |
|
AC Inrush current |
Cold-start current 20A/115V 40A/230V |
||||
Leakage current |
<0.5mA/240VAC |
||||
PROTECTION |
Overload |
110 ~ 150% rated output power |
|||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||
Over-voltage |
Protection type : Shut down o/p voltage, re-power on to recover |
||||
13.8-16.2V |
28.8-33.6V |
41.4-48.6V |
55.2-64.8V |
||
Short Citcuit |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SAFETY |
Setup rise hold up time |
200ms,100ms,20ms |
|||
Vibration |
10~500Hz,2G 10min./1cycle,Period for 60min,EACH AXES |
||||
Withstand voltage |
Input and output interval,1.5KVAC,Input and enclosure,1.5KVAC,Output and enclosure,0.5KVAC |
||||
Isolation resistance |
Input and output interval,Input and enclosure,Output and enclosure,500VAC/100M Ohms |
||||
ENVIRONMENT |
Temperature coefficient |
±0.03%/°C (0~50°C ) |
|||
Working temperature and humidity |
-20~+60°C,20~90%RH |
||||
Store temperature and humidity |
-40°C~+85°C,10~95%RH |
||||
OTHER |
Overall dimension |
308*53*22mm |
|||
Weight |
0.4Kg |
||||
CERTIFICATE |
CE EMC Authenticate |
EN55022:2010 EN61000-3-2:2006+AL:2009 EN61000-3-3:2008 |
|||
EN55024:2010 EN55015:2006+AL2007+2009 EN61547:2009 |
|||||
CE LVD Authenticate |
EN61347-1:2008T A1:2001 EN61347-2-13:2006 |
||||
EN60950-1:2006+A11:2009+A1:2010+A12:2001 |
|||||
ROHS Authenticate |
EPA3050B:1996 EN1122B:2001 EPA3052:1996 EPA3060A:1996 |
||||
EPA7196A:1992 EPA3540C:1996 EPA8270D:2007 IEC62321:2008 |