Tel: +86 577 62602806Phone: 86-18106781616E-mail: wode@wodeps.com

Mobile: 86-18106781616
Tel: +86 577 62602806
Fax: +86 577 62602807
E-mail: wode@wodeps.com
Add: Taikai 6 follor,Xiangyang Industrial Zone,Liushi Town, Yueqing City,Zhejiang Province, China
| 
				 MODEL  | 
			
				 S-50-5  | 
			
				 S-50-12  | 
			
				 S-50-24  | 
			
				 S-50-48  | 
		|
| 
				 OUTPUT  | 
			
				 DC voltage  | 
			
				 5V  | 
			
				 12V  | 
			
				 24V  | 
			
				 48V  | 
		
| 
				 Rated current  | 
			
				 10A  | 
			
				 4.2A  | 
			
				 2.2A  | 
			
				 1.1A  | 
		|
| 
				 Current range  | 
			
				 0 ~ 10A  | 
			
				 0 ~ 4.2A  | 
			
				 0 ~ 2.2A  | 
			
				 0 ~ 1.1A  | 
		|
| 
				 Rated power  | 
			
				 50W  | 
			
				 50.4W  | 
			
				 52.8W  | 
			
				 52.8W  | 
		|
| 
				 Ripple & noise  | 
			
				 100mVp-p  | 
			
				 120mVp-p  | 
			
				 200mVp-p  | 
			
				 240mVp-p  | 
		|
| 
				 Voltage ADJ. range  | 
			
				 ±10%  | 
			
				 ±10%  | 
			
				 ±10%  | 
			
				 ±10%  | 
		|
| 
				 Setup,rise,hold time  | 
			
				 800ms, 30ms,20ms/230VAC  | 
		||||
| 
				 INPUT  | 
			
				 Voltage range  | 
			
				 85~132VAC / 176~264VAC selected by switch 230~370VDC  | 
		|||
| 
				 Frequency range  | 
			
				 47 ~ 63Hz  | 
		||||
| 
				 Efficiency  | 
			
				 78%  | 
			
				 80%  | 
			
				 83%  | 
			
				 84%  | 
		|
| 
				 Ac current  | 
			
				 1.2A/115VAC 0.6A/230VAC  | 
		||||
| 
				 Inrush current  | 
			
				 Cold start 45A  | 
		||||
| 
				 Leakage current  | 
			
				 <2mA/240VAC  | 
		||||
| 
				 PROTECTION  | 
			
				 Overload  | 
			
				 115 ~ 150% rated output power  | 
		|||
| 
				 Protection type : Constant current limiting, recovers automatically after fault condition is removed  | 
		|||||
| 
				 Over voltage  | 
			
				 5.8~6.8V  | 
			
				 14~16.5V  | 
			
				 28~32V  | 
			
				 55~64V  | 
		|
| 
				 Protection type :Shut off  | 
		|||||
| 
				 ENVIRONMENT  | 
			
				 Working temp,humidity  | 
			
				 -10℃ ~ +60℃,20% ~ 90% RH non-condensing  | 
		|||
| 
				 Storage temp,humidity  | 
			
				 -20℃ ~ +80℃,10% ~ 95% RH non-condensing  | 
		||||
| 
				 Withstand vibration  | 
			
				 10 ~ 500Hz, 2G 10min/1cycle,period for 60min. each axes  | 
		||||
| 
				 SAFETY & EMC  | 
			
				 Safety standard  | 
			
				 Design refer to UL1012,EN60950-1,EN61347-1,EN-61347-2 approved  | 
		|||
| 
				 Withstand voltage  | 
			
				 I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  | 
		||||
| 
				 Isolation resistance  | 
			
				 I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC  | 
		||||
| 
				 EMC standard  | 
			
				 EN55015,EN55022,EN55024,EN61000-3-2,EN61000-3-3,EN61547 approved  | 
		||||
| 
				 OTHERS  | 
			
				 MTBF  | 
			
				 400K hrs  | 
		|||
| 
				 Dimension  | 
			
				 159*97*38mm (L*W*H)  | 
		||||
| 
				 NOTE  | 
			
				 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.  | 
		||||
| 
				 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  | 
		|||||
| 
				 3. Tolerance : includes set up tolerance, line regulation and load regulation.  | 
		|||||